Incoming Distribution Switchboards (VRP)

General information

Incoming-distribution devices VRP, UVR (ВРП, УВР) are designed (depending on panel type) for receiving, distributing and metering three-phase AC electric power with a voltage of 380/220 V, frequency 50 Hz, with a solidly earthed neutral, as well as for protecting lines against overloads and short-circuit currents.

The devices are designed for installation in electrical switchgear rooms. Wire and cable entry/exit is provided from below. The devices are manufactured for single-sided (front) access and are intended for operation in residential, communal-domestic and public buildings. Use of the devices at other facilities with a similar power supply scheme is permitted.

The VRP switching apparatus is of air-type and moulded-case design (switch-disconnectors, ПН-2/ППН fuses, MCCB/ACB circuit breakers, current transformers). The specific composition and ratings are selected for the project as per the technical specification (TS).

  • Rated operating mode — continuous.
  • Climatic design — U3.
  • Degree of protection — IP30, IP00 from the bottom side.
  • Busbar (rated) current — generally up to 1000 A (per project).

The devices comply with DSTU EN 61439-1, DSTU IEC 60439-1 and the manufacturer's own technical specifications (TU). VRP units are manufactured to order per the technical specification; ratings, apparatus set and panel layout are determined by the project.

Main technical characteristics (typical panel designs)

Panel typeRated current, ACurrent transformers T-0.66Outgoing lines (CB), ALighting controlDiagram (Fig. No.)
RatioQty63100250
Incoming panels
PVR 1201250300/561
PVR 1202250200/563
PVR 1203250200/5; 100/53; 31
PVR 1401400400/561
PVR 1402400400/5; 300/53; 33
PVR 1403400400/5; 100/53; 31
VRP-1-11-10250300/561
VRP-1-12-10250300/532
VRP-1-13-20400400/561
VRP-1-14-20400400/532
VRP-1-17-70100100/534
VRP-1-18-80250200/534
Incoming-distribution panels
PVR 2201250300/5386Automatic5
PVR 2202250300/5; 100/53; 386Automatic6
PVR 2203250300/5386Automatic7
PVR 2204250300/5; 100/53; 386Automatic8
VRP-1-21-10200200/5324None9
VRP-1-22-53200145Automatic10
VRP-1-22-54200145Manual11
VRP-1-22-5520085Automatic12
VRP-1-22-5620085Manual13
VRP-1-23-53200200/53145Automatic14
VRP-1-23-54200200/53145Manual15
VRP-1-23-55200200/5385Automatic16
VRP-1-23-56200200/53841Manual17
VRP-1-24-53200100/53145Automatic18
VRP-1-24-54200100/53145Manual19
VRP-1-24-55200100/5385Automatic20
VRP-1-24-56200100/53841Manual21
VRP-1-25-63200145Automatic22
VRP-1-25-642001441Manual23
VRP-1-25-65200841Automatic24
VRP-1-25-66200100/53841Manual25
VRP-1-26-63200200/53145Automatic26
VRP-1-26-64200200/531441Manual27
VRP-1-26-65200200/5341None28
VRP-1-26-66200841Manual29
VRP-1-27-63200100/53145Automatic30
VRP-1-27-64200100/531441Manual31
VRP-1-27-65200100/53841Automatic32
VRP-1-27-66200100/53841Manual33
VRP-1-28-63200100/53145Automatic34
VRP-1-28-64200200/531441Manual35
VRP-1-28-65200100/53841Automatic36
VRP-1-28-66200200/531441Manual37
VRP-1-29-63200200/56145Automatic38
VRP-1-29-64200200/561441Manual39
VRP-1-29-65200200/56841Automatic40
VRP-1-29-66200200/5685Manual45
Distribution panels
PVR 3001200305+22Manual41
PVR 3002200305+22Automatic42
PVR 3003200305+5Manual43
PVR 3004200305+5Automatic44
VRP-1-41-002007+2None46
VRP-1-42-01200307+2Automatic
VRP-1-42-01200307+2Manual
VRP-1-43-00200300/537+2None47
VRP-1-44-0020072None
VRP-1-45-012003072Automatic
VRP-1-45-022003072Manual
VRP-1-46-00200300/5372None47
VRP-1-47-002005+5None48
VRP-1-48-03200145+5Automatic49
VRP-1-48-04200165+5Manual50
VRP-1-49-002005+5None48
VRP-1-49-03200145+5Automatic49
VRP-1-49-04200165+5Manual50
VRP-1-50-004004+4None
VRP-1-50-01400304+4Automatic51
VRP-1-50-02400304+4Manual52

The designs shown are typical; the apparatus composition and ratings are refined per project as per the technical specification. Manufacturer — LK Energy Group, Odesa.

Dimensions

Incoming Distribution Switchboards (VRP) — Dimensions

Diagram grid

Show all images (15)
Incoming Distribution Switchboards (VRP) — Diagram grid
Incoming Distribution Switchboards (VRP) — Diagram grid
Incoming Distribution Switchboards (VRP) — Diagram grid
Incoming Distribution Switchboards (VRP) — Diagram grid
Incoming Distribution Switchboards (VRP) — Diagram grid
Incoming Distribution Switchboards (VRP) — Diagram grid
Incoming Distribution Switchboards (VRP) — Diagram grid
Incoming Distribution Switchboards (VRP) — Diagram grid
Incoming Distribution Switchboards (VRP) — Diagram grid
Incoming Distribution Switchboards (VRP) — Diagram grid
Incoming Distribution Switchboards (VRP) — Diagram grid
Incoming Distribution Switchboards (VRP) — Diagram grid
Incoming Distribution Switchboards (VRP) — Diagram grid
Incoming Distribution Switchboards (VRP) — Diagram grid
Incoming Distribution Switchboards (VRP) — Diagram grid

RPNN cabinet design

Incoming Distribution Switchboards (VRP) — RPNN cabinet design
Incoming Distribution Switchboards (VRP) — RPNN cabinet design
Incoming Distribution Switchboards (VRP) — RPNN cabinet design
Incoming Distribution Switchboards (VRP) — RPNN cabinet design
Incoming Distribution Switchboards (VRP) — RPNN cabinet design
Incoming Distribution Switchboards (VRP) — RPNN cabinet design

Description and purpose

An incoming distribution switchboard (VRP/UVR) is a low-voltage 0.4 kV (380/220 V, 50 Hz) switchgear assembly for receiving, distributing and metering electricity at the point of entry into a building or facility, with protection of the lines against overloads and short circuits. The assembly's rated current varies depending on the configuration, typically up to 1000 A. Ratings, the set of apparatus (disconnect switches, PN-2/PPN fuses, circuit breakers, current transformers, metering unit) and the panel layout are engineered to your project specification. LK Energy Group is an Odesa-based manufacturer of switchgear equipment, in business since 2005: we design and build VRPs for your specific task, with a warranty and compliance with current standards.

Technical datasheet (PDF) ↓Questionnaire for calculation →

Questions & answers

FAQ

What is a VRP/UVR and which facilities is it designed for?
A VRP (incoming distribution switchboard) is a low-voltage 0.4 kV switchgear assembly installed at the point where the supply cable enters a building. It receives electricity, meters it, and distributes it among consumers (apartments, offices, floor-level panels, workshops), while also protecting the lines against overloads and short-circuit currents. It is used in residential, municipal/utility, public and industrial facilities with a similar power-supply arrangement.
What current is the VRP rated for?
The busbar (rated) current depends on the configuration and the apparatus selected, and is typically up to 1000 A. The specific rating is determined by the project design to match your load. If higher currents are required, we develop an individual solution to your specification.
Is it a standard design or built to project specification?
The VRP is manufactured to order according to your specification. The project design determines the rated current, the composition of the incoming and outgoing apparatus (disconnect switches, PN-2/PPN fuses, circuit breakers, current transformers), the metering unit, and the number and layout of the panels. A typical example: an incoming panel with a disconnect switch and current transformers for metering, plus distribution panels with groups of circuit breakers for outgoing lines, combined in a single assembly.
Can incoming supply, metering and distribution be combined in a single VRP?
Yes. Most VRP configurations combine the incoming apparatus, the metering unit and groups of circuit breakers for outgoing lines within a single cabinet (or an assembly of several panels). For smaller facilities, the VRP effectively serves as the main distribution board.
What standards does LK Energy equipment comply with?
VRPs are manufactured in accordance with DSTU EN 61439-1 / DSTU IEC 60439-1 (Ukrainian national standards) and the manufacturer's own technical specifications. Climatic design and degree of protection (typically IP30, IP00 on the underside) are agreed to match the operating conditions. The switching apparatus is of the air-break and molded-case type (disconnect switches, fuses, circuit breakers); these are 0.4 kV devices for the reception, metering and distribution of electricity.

Price request:
Incoming Distribution Switchboards (VRP)

Send us your single-line diagram or specification — we will estimate the configuration, lead time and price. Preliminary estimate within 24 business hours.