Home/For Designers

For designers: standard solutions and DWG library by LK Energy Group

A library of ready standard solutions for power supply designers: single-line diagrams, protection (RZA) schematics, questionnaires and layouts from 0.4 to 35 kV, grouped by object type so the right diagram is 2–3 clicks away.

PDF schematics are open without registration; the full DWG set is available after a short registration (name, phone, e-mail).

Relay protection library for designers →

Classifier

Standard solutions by object

Single-line diagrams of 10 kV distribution points and KSO cubicles, 10/0.4 kV substations and KTP questionnaires, ATS schemes for two inputs — by object type and voltage class.

RP switchgear and KSO cubicles 6–10 kV6–10 kV6 solutions
TP and KTP substations 10(6)/0.4 kV0.4 kV6–10 kV5 solutions
Outdoor switchgear KRUN 10 kV6–10 kV1 solution
ShchO-90, VRU and metering 0.4 kV0.4 kV5 solutions
ATS, AFLS and backup supply 0.4–35 kV0.4 kV6–10 kV35 kV3 solutions
Genset (DGU) enclosure and foundation (0.4 kV backup)0.4 kV1 solution
Temporary power supply 0.4 kV0.4 kV1 solution
Relay protection libraryprotection relays, functions, standards
23 · Library

All standard solutions — PDF and DWG

Standard Design: PSTS (Pole-Mounted Transformer Substation) 10/0.4 kVPole-mounted transformer substation PSTS 10/0.4 kV: pole-mounted layout, inquiry sheet and LV switchboard diagrams from the manufacturer — PDF openly available, DWG after registration.ЛК-ТР-10-KTP-0010.4 kV6–10 kV6 PDF · 1.6 MB· DWG after registrationdiagramquestionnairedrawingStandard Solution: 6(10) kV Switchgear (RP) on KRU-E Switchgear Panels (KM-1F Envelope) with MRZS TerminalsStandard solution: 6 kV switchgear (RP) on KM-1F panels with MRZS terminals — 158 sheets of protection and automation (RZA) schematics, ATS, and central signaling. PDF freely available, DWG after registration.ЛК-ТР-10-RP-0016–10 kV14 PDF · 18 MB· DWG after registrationdiagramquestionnairealbumTypical Solution: KTP-1000/10/0.4 kV Package Substation for Solar Power Plants — Complete Set of Diagrams (RU-10, RU-0.4, ShchVP)Complete set of diagrams for a KTP-1000/10/0.4 kV package transformer substation for solar power plants: 10 kV switchgear (RU-10) on KSO-E-393 cubicles, 0.4 kV switchgear (RU-0.4) on ShchO-90 panels, ShchVP auxiliary-supply cabinet, cable schedule — 31 sheets, PDF. DWG after registration.ЛК-ТР-10-KTP-0020.4 kV6–10 kV6 PDF · 5.3 MB· DWG after registrationdiagramquestionnaireTypical Solution: KRPZ — Four-Transformer Substation 4×630 kVA 6/0.4 kVTypical solution KRPZ 4×630 kVA 6/0.4 kV: two dual-transformer KTPs (package transformer substations) in one modular building, 6 kV switchgear on KSO cells, ShchO-90 low-voltage panel with ATS. PDF is open access, DWG after registration.ЛК-ТР-10-KTP-0030.4 kV6–10 kV5 PDF · 2.1 MB· DWG after registrationquestionnairedrawingStandard Solution: Temporary Construction Site Power Supply CabinetStandard solution for a temporary construction site power supply cabinet: 400 A incoming supply, contactor with remote disconnect, 6 branch circuits. PDF is open access, DWG available after registration.ЛК-ТР-04-TYM-0010.4 kV2 PDF · 866 KB· DWG after registrationdiagramTypical Solution: VRU/VRP — Incoming Distribution Devices for BuildingsTypical solution for 0.4 kV main incoming distribution boards (VRU/VRP): working drawings for 400 A and 1600 A cabinets — single-line diagrams, secondary circuits, bills of materials. PDF open access, DWG after registration.ЛК-ТР-04-SHCHO-0010.4 kV3 PDF · 1.5 MB· DWG after registrationdiagramStandard solution: AFLS cabinet — automatic frequency load shedding 35/10 kVStandard solution for a 35/10 kV AFLS cabinet based on the RZM-A.ACHR device: a separate cabinet and an OPU (general substation control point) panel, FAAR circuits and signaling. PDF diagrams are open access, DWG set after registration.ЛК-ТР-35-AVR-0016–10 kV35 kV2 PDF · 1.5 MB· DWG after registrationdiagramTypical Solution: Terminal Boxes (Terminal Cabinets) YAZTS, YAZTN, YAZV for 35–220 kV SubstationsTypical solution for 35–220 kV substations: terminal boxes (terminal cabinets) YAZTS, YAZTN, YAZV — CT, VT and circuit breaker circuits. PDF diagrams open access, DWG after registration.35 kV110 kV220 kV5 PDF · 2.7 MB· DWG after registrationdiagramStandard Solution: YAVU — 0.4 kV Service Entrance and Metering CabinetStandard wiring diagrams for the YAVU — 0.4 kV service entrance and metering cabinet: overhead-line supply, GAMA300 metering via current transformers, IP54. PDF freely available, DWG after registration.ЛК-ТР-04-SHCHO-0020.4 kV2 PDF · 214 KB· DWG after registrationdiagramStandard solution: KSO cubicle retrofit — vacuum circuit breakers replacing outdated switchgearStandard solution for retrofitting a 6 kV switchgear unit: 16 KSO-E cubicles, size 393, VV/VL and HGV vacuum circuit breakers, RS83 protection. PDF diagrams openly available, DWG set after registration.ЛК-ТР-10-RP-0026–10 kV12 PDF · 7.9 MB· DWG after registrationdiagramquestionnairedrawingStandard Solution: 6 kV KTP and KRP Package Substations for a Solar Power Plant (1 MW Block)Standard solution for power evacuation from a solar power plant: block-type KTP-1250 kVA package substation + 6 kV KRP switchgear on KRUN-E cells. Questionnaires are open access; DWG package of protection-relay schematics available after registration.ЛК-ТР-10-KTP-0040.4 kV6–10 kV3 PDF · 1.3 MB· DWG after registrationquestionnaireStandard solution: 0.4 kV ATS cabinet — DEP/DGU backupReady-made 0.4 kV ATS cabinet diagrams with DEP/DGU backup and connection cabinets for two DEPs, 250–630 A. Free PDF, DWG set after registration.ЛК-ТР-04-AVR-0020.4 kV4 PDF · 855 KB· DWG after registrationdiagramStandard Solution: 10/0.4 kV Package Transformer Substation with Low-Voltage Switchgear — Diagrams, Questionnaires (PDF/DWG)Standard solution for a 10/0.4 kV package transformer substation with low-voltage switchgear (RUNN): single-line diagrams for 400 and 630 kVA, questionnaires, an overall dimension drawing. PDF is open access, the DWG package is available after registration.ЛК-ТР-10-KTP-0050.4 kV6–10 kV8 PDF · 663 KB· DWG after registrationdiagramquestionnairedrawingTypical Solution: KRUN — Outdoor-Installation Switchgear Cells 10 kVReady-made relay protection and automation schematics for outdoor-installation KRUN 10 kV switchgear: 148 sheets, 2 configurations — incomers, bus-section breaker with ATS, feeders, VT, and station-service transformer cells. PDF open access, DWG after registration.ЛК-ТР-10-KRUN-0016–10 kV18 PDF · 17 MB· DWG after registrationdiagramquestionnairealbumStandard Solution: 10 kV KSO Switchgear Cubicles with VV/TEL Breakers and RS83-AV2Standard solution: 10 kV KSO switchgear cubicles with VV/TEL breakers and RS83-AV2 — 34 sheets of protection and automation (relay protection) diagrams, ATS-SN (automatic transfer switch for auxiliary supply), inspection sheet. PDF openly available, DWG set after registration.ЛК-ТР-10-RP-0036–10 kV9 PDF · 10 MB· DWG after registrationdiagramquestionnairedrawingalbumTypical Solution: UKM — 0.4 kV Reactive Power Compensation UnitTypical schematic diagrams of UKM — 0.4 kV reactive power compensation units at 40, 110 and 320 kVAr, and as part of the ShchO 90 switchboard. PDF is open access, DWG after registration.ЛК-ТР-04-SHCHO-0050.4 kV5 PDF · 641 KB· DWG after registrationdiagramStandard Solution: 0.4 kV Switchboard on ShchO-90 Panels for a Two-Transformer Indoor Transformer Substation (ZTP)A ready-made set of diagrams for a 0.4 kV ShchO-90 switchboard for a two-transformer indoor transformer substation (ZTP): specification sheet, incomers, sectionalizing panel with ATS, feeder panels. PDF open access, DWG after registration.ЛК-ТР-04-SHCHO-0030.4 kV5 PDF · 1.0 MB· DWG after registrationdiagramquestionnaireStandard Solution: 10 kV RP on KSO Switchgear Cubicles — Full Set of Protection and Automation SchematicsA ready-made set of protection and automation (RZA) schematics for a 10 kV RP on KSO switchgear cubicles: 108 sheets in 10 sections — incomers, bus-tie with ATS, feeder lines, VTs, station-service transformers. PDF is open access, DWG package after registration.ЛК-ТР-10-RP-0046–10 kV14 PDF · 14 MB· DWG after registrationdiagramquestionnairedrawingalbumStandard solution: protective enclosure (steel box) and foundation for a DGStandard solution for the outdoor installation package of a standby diesel generator: steel box, monolithic reinforced-concrete foundation, exhaust gas outlet and earthing loop. PDFs are open access.ЛК-ТР-04-DGU-0010.4 kV1 PDF · 573 KBdrawingStandard solution: telemetry and auxiliary supply of a 10 kV distribution pointStandard solution for the auxiliary cabinets of a 10 kV distribution point: auxiliary supply cabinet (ShVP), ShO1/ShO2 cabinets and telemetry cabinet (TM). Free full DWG set after registration.ЛК-ТР-10-RP-0056–10 kVno PDF· DWG after registrationStandard solution: commercial metering cabinet 0.4/10 kV (AMR metering unit)Standard solution for a ShU-series commercial electricity metering cabinet: meter, current transformers, test terminal box, IP54/IP21 versions, AMR-ready. DWG set after registration.ЛК-ТР-10-SHCHO-0040.4 kV6–10 kVno PDF· DWG after registrationStandard solution: relay protection circuit set for a KSO cubicle (RS83-AV2 / MRZS)Standard solution for the relay protection fit-out of a KSO-10 kV cubicle: RS83-AV2/AV3 or MRZS relays, breaker failure (УРОВ), busbar logic protection (ЛЗШ), UFLS, 220 V DC operative supply. Complements the KSO set. DWG set after registration.ЛК-ТР-10-RP-0066–10 kVno PDF· DWG after registrationStandard solution: 0.4 kV ATS for two incoming feeders (power + control circuits)Standard solution for a classic mains 0.4 kV two-incomer ATS: power circuits and time-delayed control circuits, mutual interlock, frame sizes up to 630 A. DWG set after registration.ЛК-ТР-04-AVR-0030.4 kVno PDF· DWG after registration
Drawing catalogue

PDF albums

All sets of the drawing catalogue that have a PDF — as an album per group or as the full album in three volumes.

The album contains the sets that have a PDF. Cover, contents by voltage class with page numbers, bookmarks for every set and sheet. The album is in Ukrainian.

Equipment

Equipment for your projects

LK serial equipment by voltage class — in the catalogue:

Need a solution for your project?

Send us your single-line diagram or technical specification — we'll select a standard solution and provide a questionnaire sheet and specification.

+380 67 104 94 91
Project request

Send your single-line diagram or specification to info@lk-energy.com.ua — or we will contact you and ask.