Home/Equipment/Prefabricated single-front-access switchgear cubicles, type KSO-E (size 219)

Prefabricated single-front-access switchgear cubicles, type KSO-E (size 219)

General information

KSO-E (КСО-Е) Single-Front Assembled Switchgear Cells

KSO cubicles in Ukraine are built by LK Energy Group: 6, 10 and 20 kV as standard; 35 kV to order. Frame 219 is the 6 and 10 kV version with a 600 mm front. Production — Odesa.

KSO-E cells are designed for the reception and distribution of three-phase alternating current electrical energy at 50 Hz in networks with an isolated neutral or a neutral grounded through an arc-suppression reactor. LK Energy Group manufactures KSO-E cells for 6, 10 and 20 kV as a standard product; versions for 35 kV are available to order according to technical specifications (short-circuit currents and ratings for this class are determined on a project-specific / TOR basis). Switching — vacuum; no SF6 gas-insulated version is available. Enclosure — a riveted assembled structure made of galvanised cold-formed profiles, with optional RAL powder coating.

The cells are equipped with main devices and protection elements according to the ordering scheme; secondary wiring diagrams are developed for each individual project. Manufactured in accordance with our own technical specifications.

Technical characteristics (standard version, 6 / 10 kV)

ParameterValue
Rated voltage6 / 10 kV (standard); 35 kV (to order per technical specifications)
Highest operating voltage7,2 / 12 kV (standard); 24 / 40,5 kV (to order)
Rated current of main circuits (6 / 10 kV)630 / 1000 A
Electrodynamic withstand of main circuits (6 / 10 kV)51 kA (63 kA at 10 kV)
Thermal withstand of main circuits, 3 s (6 / 10 kV)20 kA (25 kA at 10 kV)
Rated current and short-circuit currents for 20 / 35 kVproject-specific / per TOR
Switching typevacuum circuit breaker (type — project-specific)
Version (dimensions)KSO-393 / 393V / 393VM / 393M-V / 272 / 285 / 20 / 219 / 35; narrow "U" version — 600 mm
Regulatory basisManufacturer's own technical specifications

Specific main circuit diagrams, devices and dimensions are selected for your project. Send us a data sheet (questionnaire) — we will prepare a solution.

Overall dimensions

Prefabricated single-front-access switchgear cubicles, type KSO-E (size 219) — Overall dimensions
Prefabricated single-front-access switchgear cubicles, type KSO-E (size 219) — Overall dimensions
Prefabricated single-front-access switchgear cubicles, type KSO-E (size 219) — Overall dimensions
Prefabricated single-front-access switchgear cubicles, type KSO-E (size 219) — Overall dimensions
Prefabricated single-front-access switchgear cubicles, type KSO-E (size 219) — Overall dimensions

Diagram grid

Show all images (25)
Prefabricated single-front-access switchgear cubicles, type KSO-E (size 219) — Diagram grid
Prefabricated single-front-access switchgear cubicles, type KSO-E (size 219) — Diagram grid
Prefabricated single-front-access switchgear cubicles, type KSO-E (size 219) — Diagram grid
Prefabricated single-front-access switchgear cubicles, type KSO-E (size 219) — Diagram grid
Prefabricated single-front-access switchgear cubicles, type KSO-E (size 219) — Diagram grid
Prefabricated single-front-access switchgear cubicles, type KSO-E (size 219) — Diagram grid
Prefabricated single-front-access switchgear cubicles, type KSO-E (size 219) — Diagram grid
Prefabricated single-front-access switchgear cubicles, type KSO-E (size 219) — Diagram grid
Prefabricated single-front-access switchgear cubicles, type KSO-E (size 219) — Diagram grid
Prefabricated single-front-access switchgear cubicles, type KSO-E (size 219) — Diagram grid
Prefabricated single-front-access switchgear cubicles, type KSO-E (size 219) — Diagram grid
Prefabricated single-front-access switchgear cubicles, type KSO-E (size 219) — Diagram grid
Prefabricated single-front-access switchgear cubicles, type KSO-E (size 219) — Diagram grid
Prefabricated single-front-access switchgear cubicles, type KSO-E (size 219) — Diagram grid
Prefabricated single-front-access switchgear cubicles, type KSO-E (size 219) — Diagram grid
Prefabricated single-front-access switchgear cubicles, type KSO-E (size 219) — Diagram grid
Prefabricated single-front-access switchgear cubicles, type KSO-E (size 219) — Diagram grid
Prefabricated single-front-access switchgear cubicles, type KSO-E (size 219) — Diagram grid
Prefabricated single-front-access switchgear cubicles, type KSO-E (size 219) — Diagram grid
Prefabricated single-front-access switchgear cubicles, type KSO-E (size 219) — Diagram grid
Prefabricated single-front-access switchgear cubicles, type KSO-E (size 219) — Diagram grid
Prefabricated single-front-access switchgear cubicles, type KSO-E (size 219) — Diagram grid
Prefabricated single-front-access switchgear cubicles, type KSO-E (size 219) — Diagram grid
Prefabricated single-front-access switchgear cubicles, type KSO-E (size 219) — Diagram grid
Prefabricated single-front-access switchgear cubicles, type KSO-E (size 219) — Diagram grid

Description and purpose

Frame 219 is the narrower version of the KSO-E series: the reduced-width cubicle measures 600 mm across the front, against 650 mm in frame 393. We do build this version — ratings and the single-line diagram are selected to the customer’s project or technical specification. It is chosen where the switchroom is tight and every centimetre of frontage counts: rated main-circuit current 630 / 1000 A — the same range as in frame 393. Rated voltage is 6 and 10 kV; 35 kV versions are built to order per the technical specification. Switching is vacuum; electrodynamic withstand of main circuits 51 kA, thermal withstand 20 kA for 3 s; at 10 kV — 63 kA and 25 kA.

The purpose, primary connection diagrams, series composition and applications are described on the main page — KSO-E cubicles, frame 393.

Technical datasheet (PDF) ↓Questionnaire for calculation →

Five questions

Find the right equipment for your site

Answer them and we will come back with a configuration and a ballpark price for your site.

Question 1 of 5
What do you need?
Questions & answers

FAQ

What voltage levels does LK Energy Group manufacture KSO-E cubicles for?
As standard production — for 6, 10 and 20 kV; for 6 and 10 kV with vacuum circuit breakers. A 35 kV version is available to order per technical specifications. Ratings (main circuit current, short-circuit currents, cubicle scheme) are selected according to the customer's project or technical specification.
What switching devices are used in KSO-E?
Fixed-mounted vacuum circuit breakers and disconnectors; the specific circuit breaker type is selected for the project. There is no SF6 (gas-insulated) design — only vacuum switching.
Can a cubicle be ordered for a specific single-line diagram?
Yes. KSO-E is made-to-order equipment: dimensions, rated current and the cubicle scheme are manufactured according to your project or technical specification. Before ordering, agree the specifications with our engineer.
What is the difference between KSO and KRU?
KSO has single-front access and fixed-mounted devices — more compact and less expensive, for indoor installation in indoor switchgear/indoor transformer substations. KRU (metal-clad switchgear with withdrawable trucks) has withdrawable trucks and double-front access, for facilities requiring redundancy. See the comparison table on the page for details.
How long does manufacturing take, and what is the warranty?
The estimated manufacturing lead time is about 1 month, depending on the scheme and current workload. The warranty is 2 years (extended to 5 years by agreement); enclosure metalwork — 10 years. Installation and commissioning are carried out by our specialists.

Price request:
Prefabricated single-front-access switchgear cubicles, type KSO-E (size 219)

Send us your single-line diagram or specification — we will estimate the configuration, lead time and price. Preliminary estimate within 24 business hours.

+380 67 104 94 91
Request a quote

Send your single-line diagram or specification to info@lk-energy.com.ua — or we will contact you and ask.